      • <mark id="j4di7"></mark>
      • <big id="j4di7"></big>

        久久久久亚洲av无码专区首jn_又污又黄又无遮挡的网站_a级无遮挡超级高清-在线观看_欧美性大战xxxxx久久久

        Diagnostic unit I plus User Manual_3-E

        來源: 2020/9/25 11:57:20 點擊:

        Diagnostic unit I plus User Manual_3-E

        Page - 1 - of 8
        Diagnostic Unit I plus User Manual (V2.1)
        Brief
        “I plus” increases to download and upload the characteristic program of MC (MC1、MC2、MC3) main board
        based on original model, and saves the downloaded characteristic program of MC board into diagnostic unit I. It
        has relative software which can backup downloaded characteristic programs in computers, or can upload
        characteristic programs to diagnostic unit.
        When do maintenance debugging on site, “I plus” is very convenient to solve many problems for long-service life
        elevator projects due to characteristic program missing in main chipset, chipset damaged, or fake chipset etc…
        and will not be worried about the trouble to replace main board but no chipset.
        “I plus” needs to copy some parameters when replace MC board, it only takes few steps, and debugs other items:
        well teach-in(AF10), rated speed(AF16), speed correction, external call scan(AF0C).
        Usage Steps
         Keys and status switch operation.
        “I plus” diagnostic unit appearance(Pic 1)
        Here is a USB
        port 
        Page - 2 - of 8
         Pic 2
        a. switch from normal debugging operation interface to parameter operation interface: in Pic 2, press “+”
        “-” key at the same time until the first digit dot on the right light on, and diagnostic unit will switch into parameter
        copy menu showed as pic 3. If it shows as pic 3, it enters into parameter operation interface.
         Pic 3
        b. switch from parameter operation interface to normal debugging operation interface : In pic 3, press “+”
        “-” key at the same time until the first digit dot on the right light on, the diagnostic unit back to normal debugging
        status. (From pic 3 status to pic 2 status.)
        c. enter into parameter operation interface as pic 3, press “+” or “-” key, can page up or down to check parameters.
        “P - - 0”, “P - - 1”…… “P - - 9”. This device can save 0~9 parameters. If the display is dark, which means
        the program is empty in this number, and it display light, it means the program is valid in this number.
         Sub-Menu explanations and operations for four parameters.
        a. pause at “P--0” ( at 0 parameter), press “ENT” enter key, interface will switch from pic 3 to pic 4, it shows to
        enter into the Number 0 parameter menu. “0-rt” : 0 means 0 parameters, “rt” is the abbreviation of return. If press
        “ENT” key, the interface will switch back from pic 4 to pic 3.
         Pic 4
        b. press “-” key in pic 4, will show pic 5, “0-id” shows the ID for the number 0 saved parameter (normally, it
        refers to the characteristic number of elevator ). Press “ENT” key under pic 5, it will rolling display saved
        parameters ID. If the display color is dark, it means no saved parameters; it is no valid to press “ENT”, no display
        parameter ID.
         Pic 5
        c. press “-” key in Pic 5 , will show pic 6, and press twice “ENT” key , it will download MC board parameters into
        diagnostic unit I plus. (“0-dn” , “dn” is the abbreviation of download). 
        Page - 3 - of 8
         Pic 6
        d. Press “-” in pic 6 to show Pic 7, and press twice “ENT” key will upload parameters from diagnostic unit to
        main board and saved. If display color is dark ,it means don’t have valid parameters, and will not upload
        parameters and save.
         Pic 7
         Download parameters (download parameters from main board to
        diagnostic unit and save)
        Change page to this interface, “0-DN’, DN is for download, and press twice “ENT” key, will download
        parameters as below pictures.
        When downloading, the number 3. 4 digit dot on the bottom right is blinking.
        If finish parameter download, will display “SUCC” , it means to save parameters successful. 
        Page - 4 - of 8
         Parameters upload. (upload parameters from diagnostic unit to main
        board and save) -Must be in the inspection state
        Change page to this interface, “0-UP”, it means upload, press twice “ENT” key, and will upload parameters
        from diagnostic unit to main board as below pictures.
        When uploading, the number 3. 4 digit dot on the bottom right is blinking
        Display “SAVE ”, it means the parameters has been received successfully, and main board is saving parameters.
        Please don’t touch the communication cable and diagnostic unit at this time.
        It will display “SUCC” when parameters is uploaded and saved successfully. At the same time, please power off
        main power supply and restart elevator main board.
         Supplementary explanation about upload and download from main
        board. 
        Page - 5 - of 8
        If shows “E-XX” , it means the relative operation is error, Please check the main board status, communication
        cable etc…
        Explanations of Error codes :
        E—10 error from downloading data
        E—11 error from downloading data timeout
        E—12 An error occurred while downloading data and fail to save.
        E—00 invalid uploaded data
        E—01 error from uploading data
        E—02 error from uploading data timeout
        E—03 version error while uploading data
        E—04 error from uploading data, please restart main board
        E—05 error from saving codes while uploading data.
        E—06 error from saving operation while uploading data
        E—20 unknown error
         Backup characteristic program to computer
         Restore characteristic program to diagnostic unit
         The code meaning when copy parameters from diagnostic unit.
        Software Operations:
        1. upload file from computer to diagnostic unit
        1
        2. open serial
        port
        3. select needed
        spec upload to
        diagnostic unit
        4. select to save
        specs
        1. select COM
        port
        5. click to upload
        specs to diagnostic
        unit
        6. uploaded spec to diagnostic
        unit, successfully 
        Page - 6 - of 8
        2. download spec from diagnostic unit to computer
        3.Illustration for spec modification
        2. Input your modified spec address
        and click enter to save, and select
        it, the value for this address will be
        changed automatically. Click”
        modify” button, will show the
        modified value.
        3. click save to
        take effect.
        upline is original
        value
        downline is
        modified value
        1. upload or open the spec file, click
        “spec” in menu, and select “spec modify”
        1. select COM
        port
        2. open
        serial port
        3. select program Number for
        needed backup to computer
        4. click to download
        spec
        5、download spec successfully
        6. click to save,
        and select the
        saved route.
        Done. 
        Page - 7 - of 8
        4、data cable connection
        5. the accessories for connector changes from USB to RS232 serial port.
        this connector is only
        for diagnostic unit,
        forbid connecting with
        USB of computer.
        The short-line USB
        connector, is 5V power
        supply, when diagnostic unit
        needs 5V power supply, it can
        connect computer USB ,
        mobile phone charges or
        power charger. The short-line
        USB connector is only for
        power supply
        9-pin RS232 serial
        port is for the
        connection with board
        port of elevator’s MC
        board or RS232 of
        computer.
        2 – RXD
        3 – TXD
        5 – GND
        9 – 5V DC 
        Page - 8 - of 8
        Note: when diagnostic unit connects with computer, if computer is not with RS232 serial connector, will need this
        accessories.
        6. Distinguish
        RS232 


        下載文件:點擊下載Diagnostic unit I plus User Manual_3-E (查看下載口令
            下載說明:(1)倍加信科技提供的Diagnostic unit I plus User Manual_3-E資源僅供下載學(xué)習(xí)和參考,如果使用下載的Diagnostic unit I plus User Manual_3-E資料造成任何損失與倍加信科技無關(guān),Diagnostic unit I plus User Manual_3-E資料最終以廠家提供原廠資料為準(zhǔn)。(2)倍加信科技提供的Diagnostic unit I plus User Manual_3-E資料都來自網(wǎng)絡(luò),并免費提供下載Diagnostic unit I plus User Manual_3-E不收取任何費用,若發(fā)現(xiàn)您的權(quán)益受到侵害,請聯(lián)系我們客服,我們會立即刪除Diagnostic unit I plus User Manual_3-E。(3)倍加信科技免費提供大量蒂森電梯技術(shù)資料下載,點擊【頂部電腦官網(wǎng)按鈕】查看更多信息,倍加信科技提供了大量相關(guān)資料下載。(3)倍加信語音梯控、人臉識別梯控、二維碼梯控、IC刷卡梯控、CPU梯控、ID卡梯控、T5577卡梯控、證件乘梯、指紋識別梯控、掌靜脈梯控、手機(jī)乘梯、機(jī)器人乘梯等廣泛應(yīng)用于蒂森電梯,歡迎聯(lián)系客服咨詢了解,再次感謝您蒞臨倍加信科技下載蒂森電梯Diagnostic unit I plus User Manual_3-E。